(f)  All  equipments  as  required  to  be  provided  by  concerned  Departments
                             including a clock, and

                         (g) A name board of sufficient size.

                         Note:  The  lever  pull  chart,  referred  in  (2)  above,  need  not  be  provided  in  Cabins
                         where the number of release lever concerned are indicated on the lever name plates
                         to guide the Cabin man in following the correct sequence for pulling the levers.

                12.8.2  Numbering  of  levers:  All  levers,  including  spares,  shall  be  numbered
                         consecutively  through  the  frame  from  left  to  right.  Each  lever  shall  be
                         provided  with  a  number  plate.  This  will  show  the  function  in  the  order  of
                         operation which must precede to release when no lever description board is
                         provided.

                12.8.3  Cabins-Cleanliness, Repair and Fittings

                         (a) Ground floor of cabins shall be kept clean and tidy.


                         (b) Cabins  including  battery  room  and  repair  room  shall  be  kept  in  good
                             condition  and  periodically  painted/distempered.  The  roof  shall  be  so
                             maintained as to prevent leakage. "Ghara" stands shall be kept properly
                             drained off. Wash basins, where provided, shall be kept in perfect repair.
                             Any repair required shall be promptly notified to the SSE/JE (Woks).


                         (c) SSE/JE  (Signal)  shall  bring  to  the  notice  of  his  Sr.DSTE  or  DSTE  or
                             ADSTE incharge of the section when repairs to cabin are delayed.

                         (d) Windows of cabins shall be kept clean. This is the duty of the operating staff.

                         (e) Each SSE/JE (Signal) shall see that the cabin diagram, pull chart, Cabin
                             man's instructions and Maintained programme provided in the Cabin are
                             up-to-date and their glazed frames are in proper repair.


                                        Section 9: Maintenance of Lever Frame

                12.9.1  Responsibility: Each SSE/JE (Signal) is personally responsible for efficient
                         maintenance  of  the  locking  of  the  interlocking  frames  under  his  charge.
                         Locking  box  covers  shall  be  kept  padlocked  and  sealed  with  his  personal
                         seal supplied to him for the purpose.

                12.9.2  Instructions for Technicians


                         (a) All  accessible  working  parts  of  interlocking  frames  shall  be  thoroughly
                             lubricated and cleaned.

                         (b) All split pins shall be checked to ensure that they are intact and properly open.
                             Also all nuts and bolts shall be checked and tightened wherever necessary.


                         (c) Handles of levers of interlocking frames shall be kept clean and bright by
                             the Transportation Staff.





                              Chapter 12: Installation, Testing & Maintenance of Mechanical Signalling Equipment   Page 248 of 535